Nuclear Magnetic Resonance Project

The magnetic moment of a nucleon is sometimes expressed in terms of its g-factor (a dimensionless scalar) as , where is an intrinsic magnetic moment, is the nuclear magneton and is given by , is the nucleon's g-factor, is the nucleon's spin angular momentum number and is the nucleon's mass. The Hydrogen/Proton Gyromagnetic Ratio, , is equal to .

The proton's g-factor


So,

Larmor Frequency:

Our magnet will produce fields up to ~ 0.7T. This allows for transverse field frequencies up to ~ 30MHz. We employ a bridged-tee detector (Waring - 1952) to observe the NMR signal.


Basic Theory

(for more detailed explanations see Nuclear Magnetic Resonance - Andrew)

- The Resonance Condition

- Spin-Lattice Relaxation Time

- Spin-Spin Interactions

- Saturation

- Magnetic Susceptibilities

- Conditions for Observation of NMR Absorption


NMR Video


Links and Info:

- A Bridged Tee Detector for NMR - Waring